Linear inductive position sensor for clamping technology

Balluff's BIP linear inductive position sensor is non-contact and has linear travel of 40mm and resolution of 14 microns.

10/28/2011


Balluff's BIP linear inductive position is designed for clamping devices for tools and workpieces. Courtesy: BalluffBalluff’s BIP linear inductive position sensor has a measuring principle for position monitoring in applications such as drive spindles and clamping devices for tools and workpieces. The sensor can also be used for other linear motion applications such as punch depth, grab positions, rolling positions, valve positions, etc.

The BIP is non-contact. Linear travel of up to 40 mm can be detected. The Balluff BIP has resolution of 14 microns, repeat accuracy of +/- 80 microns and non linearity of +/- 250 microns for optimal process quality. Available outputs include 0-10 V and 4-20 mA. The sensor’s repeat accuracy allows for process quality, even in cramped locations with temperatures up to 85 C.

Mechanical adjustments are not necessary, allowing the measuring range to be adapted to the application. With the IO-Link Variant this is also possible via the control system.

www.balluff.com 

Balluff

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me