Lighting Controls Assn. adds “Hi-Bay Lighting Upgrades” to its education program

The Lighting Controls Assn. has announced the availability of EE204: Hi-Bay Lighting Upgrades, a new course added to its Education Express program.

03/19/2008


The Lighting Controls Assn. (LCA), Rosslyn,, application, system design and commissioning, as well as meta-issues such as LEED, energy codes and other trends. 
Probe-start metal halide fixtures are a common workhorse in hi-bay applications such as factories, warehouses, big-box stores and gyms, but are also the least energy-efficient. As a result, the Energy Independence and Security Act of 2007 is expected to virtually eliminate probe-start fixtures starting in 2009, forcing a choice between more-efficient pulse-start metal halide and fluorescent hi-bay fixtures. In addition, replacing probe-start with fluorescent has become one of the hottest lighting retrofit markets, as fluorescent can deliver comparable light levels and up to more than

EE204: Hi-Bay Lighting Upgrades, authored by lighting industry educator and journalist Craig DiLouie, describes pulse-start metal halide and T5HO and T8 fluorescent options, with detailed information about how to maximize energy savings and lighting’s utility using appropriate controls.

At the conclusion of the course, an optional online comprehension test is available, with automatic grading; a passing grade enables the student to claim education credit. EE204: Hi-Bay Lighting Upgrades is accredited/registered with the National Council on Quality in the Lighting Professions (NCQLP), which recognizes 4 LEUs towards maintenance of Lighting Certified (LC) certification; the Association of Energy Engineers (AEE), which recognizes 0.4 CEUs towards maintenance of its Certified Lighting Efficiency Professional (CLEP) certification; and the interNational Association of Lighting Management Companies (NALMCO), which recognizes 15 Education Points towards maintenance of its Certified Lighting Management Consultant (CLMC) certification.

Since its launch in June 2006, Education Express has served nearly 4,000 students, who have benefited from more than 13,000 completions of learning modules and nearly 5,000 comprehension tests taken online, enabling them to earn education credit.

For more information about Lighting Controls Association’s Education Express, including a complete course listing, click here .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me