Lift stage with large aperture offers precise elevation of heavy loads

Aerotech’s AVS1000 series is a high-load lift stage with aperture that offer excellent pitch, yaw characteristics over full travel.

SOURCE: Aerotech

04/22/2011


Aerotech’s AVS1000 series stages offer a solution for applications that require positioning of large or heavy loads over very small incremental movements in elevation above a horizontal plane. The low profile and precise motion capability make these stages ideal for use in semiconductor manufacturing and inspection, automated tool alignment, machine vision inspection systems, laser machining applications, and more.

The AVS1000 series provides precise elevation of a load in a vertical plane using a moving-wedge design. The precision machined wedge block converts horizontal movement from a precision-ground ball screw into vertical elevation of the AVS1000 series tabletop. Excellent pitch and yaw characteristics over the length of travel minimize the impact of angular errors. AVS1000 performance includes exceptional resolution (5 nm) and accuracy (±1 µm), with the ability to apply this performance to large loads up to 135 kg.

Sealed linear motion guide bearings with integral wipers are incorporated to provide excellent payload capability, long life, and smooth, precision motion. Stable and parallel vertical motion with no rocking or horizontal deviation of the platform is assured. Careful design of the wedge angle and bearing system allows the AVS1000 series to achieve submicron resolution and still maintain a compact profile.

The vertical lift approach offers an alternative to traditional Z-plane oriented stages. Not only do the AVS1000 series stages offer a lower profile, but the load can also be conveniently accessed from any side due to the large aperture. And by centering the payload over the bearings, there are no cantilevering effects.

The AVS1000 series includes Aerotech's high performance NEMA 34 frame-size BMS series brushless, slotless servomotor. The slotless motor has zero cogging and therefore is optimized for applications requiring very smooth motion.

Aerotech manufactures a wide range of matching drives and controls to provide a fully integrated and optimized motion solution.

The AVS1000 series specification data is available at the following link.

www.aerotech.com

Aerotech

- Edited by Gust Gianos, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.