LED floodlight series

The FLL and FXL LED floodlights are designed for office buildings, safety/security, and other applications and are listed to UL1598 for use in wet locations and are DLC qualified.

08/28/2014


The FLL and FXL LED floodlights are designed for office buildings, safety/security, and other applications and are listed to UL1598 for use in wet locations and are DLC qualified. Courtesy: Hubbell LightingHubbell Lighting's FLL and FXL LED floodlights are designed for office buildings, safety/security, and other applications. Both floodlights feature vented housings designed to isolate the LED module from the driver maximizing product life and performance and they are constructed with a heavy-duty steel yoke with adjustable stainless steel hardware. Both floodlights are listed to UL1598 for use in wet locations and are DLC qualified. The flat surface tempered glass lens protects the LEDs and allows for quick and easy cleaning and debris removal. The FLL uses 28 LEDs to deliver 8054 lumens at 80.5 lumens per watt, while the FXL uses 56 LEDS to deliver 16358 lumens at 82 lumens per watt. 

Hubbell Lighting

www.hubbelllighting.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me