SEARCH Archives
Loading
Sponsored by:

ISO 50001: The new energy management paradigm

ISO 50001 defines how facility executives can establish an energy management plan.

Michael Ivanovich, The Ivanovich Group LLC, Oak Park, Ill.

10/17/2011


The International Standards Organization recently released a new standard, ISO 50001, which has gained a lot of attention right out of the gate. ISO 50001 defines how facility executives can establish an energy management plan and integrate it with their routine business model. By implementing ISO 50001, executives can credential their organization as a conscientious energy consumer.

Three things give ISO 50001 its star appeal:

  1. ISO 50001 is applicable to any size and type of organization in any country and to every type of building using any type of energy from any source. And, it’s designed to be integrated with organizational policies and practices already in place—so organizations do not have to reinvent themselves around energy management.
  2. ISO 50001 adopters can self-certify or undergo a third-party audit, which supports small companies that can’t afford the audits, and enables the larger companies to boast their certifications. And, the ISO brand is regarded highly all over the world. This isn’t yet another new standard by yet another new organization nudging its way into the crowded green scene.
  3. ISO 50001 is wholeheartedly supported by the U.S. EPA Energy Star program and the U.S. Dept. of Energy (DOE). EPA and DOE will release tool kits in October 2011 to help organizations adopt ISO 50001, and the standard is being embedded in overarching programs, such as the Superior Energy Performance program for manufacturers.

ISO 50001’s scope applies to “variables affecting energy performance that can be monitored and influenced by the organization.” It facilitates an organization endeavoring to meet commitments for energy consumption and, if desired, also for carbon reduction. For example, a university pledging to cut greenhouse gas emissions by 20% can adopt ISO 50001 to structure how it reduces energy waste and documents the energy and carbon savings.

ISO defines an energy management system (EnMS) to include the activities of people; it’s not just about HVAC controls or BAS. That’s probably why ISO created a four-letter acronym (EnMS) instead of EMS for energy management system. Another four-letter acronym defined in the standard is PDCA, Plan–Do–Check–Act, which alludes to a long-term continual framework for energy management.

ISO 50001 does not set performance goals or building performance criteria, and it’s skimpy on the details for the measures it does require. For example, it specifies that an organization must have energy management goals, plans, processes, and documentation in place, but it does not specify their content or behavior. So, chances are pretty good that organizations with a robust energy management program already in place, such as the one long advocated by the Energy Star buildings program, will have little difficulty meeting ISO 50001.

ISO 50001 structures the PDCA of energy management in about 13 pages, including definitions. Executives can quickly read the standard and get the gist of it, which will go a long way toward giving ISO 50001 traction.

This translates into a great business opportunity for consulting engineers and commissioning firms. Consultants can help organizations develop their energy management system to ISO 50001—and perform energy audits or retro-commissioning studies that identify cost-effective conservation measures, and implement them. For applicable facilities, engineers can easily roll in Energy Star scores and certification as part of their energy goals.

Ivanovich is the president of The Ivanovich Group LLC, which provides research, analysis, and consulting services to the buildings industry. For more information, visit www.theivanovichgroup.com.Additionally, energy professionals should consider getting certified to conduct ISO 50001 audits. Exams for certified auditors begin in October 2011. This certification will be a differentiating credential tied to an international standard that is, in my estimate, going to gain traction fast.

Ivanovich is the president of The Ivanovich Group LLC, which provides research, analysis, and consulting services to the buildings industry. For more information, visit www.theivanovichgroup.com.


Word on the street

DOE’s ISO 50001 Energy Management Standard

Energetics Inc.’s Superior Energy Performance program for industrial facilities

Purchase ISO 50001



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.