ISA-S88 system reduces batch device task development

New S88-based process control system from ECS Solutions simplifies and speeds up device configuration when creating or updating batch manufacturing campaigns using Rockwell controllers.

04/30/2013


New S88-based process control system from ECS Solutions simplifies and speeds up device configuration when creating or updating batch manufacturing campaigns using Rockwell controllers.S88 Builder from ECS Solutions allows batch processors to pre-configure process devices such as valves, pumps, variable drives, or tanks, and then configures these devices into specific operating tasks such as mixing, flow control, heating, cleaning, and so on. The company says that S88 Builder provides a configuration process that is easier, more accurate, and faster than conventional programming devices and tasks, resulting in project development reductions up to 90% compared to custom programming. This capability lowers the total cost of ownership for a process control system by minimizing initial development costs, reducing time-to-market for new products and reducing waste and downtime.

The S88 Builder configuration system is based on the ISA-S88 standard that defines best practices for control operations at batch processing plants. The goal of ISA-S88 is to provide standard terminology and consistent sets of concepts and models for batch manufacturing plants and batch control. These concepts and models are the foundation of the S88 Builder process. This process includes a Studio that contains various modules to configure devices and tasks on a PC and then loads those profiles onto a PLC or PAC. The S88 Builder engine provides the runtime execution of those profiles on the controller. It incorporates faceplates and objects tools installed in an HMI to provide operator interface capabilities including task status, alarms and task management.

For now, this platform is designed specifically for Rockwell Automation PLCs, PACs, HMIs and batch management software. Systems for other brands of hardware and software are under development.

ECS Solutions

www.s88builder.com

www.ecssolutions.com

Peter Welander, pwelander@cfemedia.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me