International Code Council takes action on ASHRAE proposals

The International Codes may soon incorporate requirements from a new load calculation standard from ASHRAE and the Air Conditioning Contractors of America under several recent proposals.

03/10/2008


The

ASHRAE made 15 proposals to the ICC and after a public comment period of the committee recommendations of proposals, final hearings for the code change proposals will take place in September 2008.
If accepted, the proposals would be included in the 2009 code. Under a proposal to both the International Mechanical Code and International Energy Conservation Code, references to load calculation guidance in the ASHRAE Handbook, Fundamentals, would be replaced with requirements from a new ASHRAE standard. The new standard would be developed with the ACCA, ANSI/ASHRAE/ACCA Standard 183-2007, Peak Cooling and Heating Load Calculations in Buildings except Low-Rise Residential Buildings. The standard establishes minimum requirements for building loads that are inclusive of as many procedural methods as possible while identifying core elements that impacts heat loss and gains.
Other approved proposed changes include lighting stringency based on requirements in ANSI/ASHRAE/IESNA Standard 90.1-2007, Energy Standard for Buildings except Low-Rise Residential Buildings. The changes include adding exceptions for typical lighting requirements, which eliminate current conflicts with accepted lighting design practices, allowing for calculation of track lighting wattage, and modifying lighting power allowances.
Also related to 90.1 was a proposal to modify chiller requirements. The proposal calls for, effective Jan. 1, 2010, an additional path of compliance for water-cooled chillers and consolidation of, and new requirements, for some of the existing categories. Also approved was a proposal from ASHRAE to add new refrigerant classifications to the IMC from ANSI/ASHRAE Standard 34-2007, Designation, and Safety Classification of Refrigerants.
For more information click here .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me