International Code Council Adopts Electronic Monitoring of Fire Extinguishers


The International Code Council (ICC) voted unanimously in June to amend its International Fire Code (IFC) in order to permit electronic monitoring of fire extinguishers in lieu of 30-day physical inspections.

According to the ICC, 32 states use the IFC. Utah was the first state in the nation to adopt standards for the electronic monitoring technology. Moreover, state fire marshals in Maine, Nevada, New Hampshire and New Jersey have also given the go-ahead for occupancies to install such equipment while the necessary code changes are in process.

 

The new code language, which is endorsed by the National Association of State Fire Marshals (NASFM), does not mandate the use of electronically monitored fire extinguishers; instead it allows its use as an alternative to thirty-day physical inspections. IFC Section 906.2 was revised to include a second exception that reads, “The use of a supervised, listed electronic monitoring device shall be permitted in lieu of 30-day interval inspections, when approved.” The IFC change takes effect January 1, 2005.

 

Fire equipment industry studies show that 90% of 30-day physical inspections simply do not happen, according to John McSheffrey, vice president of MIJA, a manufacturer of this technology. “Large office towers can have hundreds if not thousands of extinguishers that must be checked manually each month—costing building operators both valuable time and money,” said McSheffrey. “In the event even one extinguisher is not properly inspected and it is not available in an emergency—the liability costs could be enormous. By implementing 24-7 electronic monitoring, safety is increased and liability is reduced.”

 

The National Fire Protection Association (NFPA) code NFPA-10 for commercial facilities requires physical inspections of fire extinguishers every 30 days for presence, position, pressurization and unobstructed access. McSheffrey says that extinguishers equipped with electronic monitoring exceed these requirements by monitoring constantly for presence and position while checking every 15 hours for pressure and obstruction to access. Fire extinguisher monitoring systems are also capable of generating a log of extinguisher readiness and impairment history, which is useful to both building owners and fire inspectors. For more information, go to www.iccsafe.org .





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me