SEARCH Archives
Loading
Sponsored by:

Integration platform designed to unite disparate systems

Fieldbus Foundation unveils Foundation for Remote Operations Management, which aims at transforming the industrial remote operations market. Video: Larry O’Brien explains the underlying technical concepts.

12/13/2011

Flash is required!

Larry O'Brien, global marketing manager for the Fieldbus Foundation, explains Foundation for ROM.



The Fieldbus Foundation has unveiled its Foundation for Remote Operations Management (ROM) solution, a new technology initiative intended to develop a unified digital infrastructure for asset management in remote applications such as tank farms, terminals, pipelines, offshore platforms, and even OEM equipment skids. The technology enables fieldbus connectivity to remote I/O and the leading industrial wireless protocols, including WirelessHART and ISA 100.11a. It provides an interface to these wireless technologies and uses Electronic Device Description Language (EDDL) and function blocks to ensure interoperability with Foundation for ROM devices.

Fieldbus Foundation global marketing manager Larry O'Brien explained, "Foundation for ROM is important because it is the first example of being able to integrate ISA 100.11a, WirelessHART, wired HART, and wired H1 protocols into a single standard environment. More importantly, it is one that does not sacrifice diagnostic capabilities of the existing wireless devices. Instead, we map these capabilities into our block structure to provide a standard environment for data management, quality, and more, eliminating today's solutions which are highly customized and much more costly to maintain throughout the plant lifecycle.

"Remote operations management is one of the fastest growing segments of the process automation business. However, it is also caught up in the turbulence of business challenges, technological change, personnel issues, and the need for operational excellence. With Foundation for ROM, industrial operations can implement a true predictive and proactive maintenance strategy for remote assets that could not previously support one. Data from devices on multiple networks, both wired and wireless, are tightly integrated into the Foundation fieldbus infrastructure, providing a single environment for management of diagnostic data, alarms and alerts, data quality, control in the field capability, and object oriented block structure."

Within the Foundation automation architecture, the H1 (31.25 kb/s) and HSE (100 Mb/s) fieldbus networks provide a distributed function block capability with HSE serving as a larger pipeline with increased speed and throughput. The new solution expands these capabilities by establishing open, non-proprietary specifications for an interface to wireless field device networks, a wired HSE backhaul, and a wireless HSE backhaul integrating various wireless sensor networks such as WiFi, satellite, cellular, and so forth. As part of this solution, it provides a way to bring large concentrations of discrete and analog field I/O back to the control room using HSE communication. This is a key element to improved integration of critical functional areas, including machinery health monitoring, safety interlocks, fire and gas detection systems, and video surveillance.

Having the ability to collect greater amounts of remote diagnostic data can provide significant improvement in labor costs by avoiding the need to send maintenance personnel on unnecessary trips to the field to check or diagnose problems with instrumentation. In the oil and gas industry, for example, having remote access to devices can reduce the exposure and risk operations personnel face in hazardous environments on an offshore platform or safety zone.

The Fieldbus Foundation contends that access to high-quality process and equipment health data ultimately increases a company's profitability by minimizing downtime and increasing production, which results from well-informed operational, maintenance, and management decisions. Experience has shown that a comprehensive remote operations management solution enables industrial organizations to respond faster to market conditions, increase efficiency, reduce downtime, and achieve higher production availability. It also minimizes the costs and risks associated with remote site visits-enabling fewer core personnel to meet the operational requirements of numerous facilities from a single secure location.

A variety of companies has participated in development of the Foundation ROM technical specifications, including: ABB, Abzil/Yamatake, Aniotek, Advanced Process Automation Technologies, Apprion, Belden/Hirschmann, Boeing, BP, Byres Security Inc./Tofino, Chevron, Cisco, Cooper Industries/MTL, EF Johnson, Emerson Process Management, Endress+Hauser, ExxonMobil, Fieldbus Diagnostics, Fieldbus Inc., General Electric, Geode Network Technologies, HART Communication Foundation, Herman Storey Consulting, Hodson Consulting, Honeywell, Industrial Automation Networks Inc., International Society of Automation, Invensys Process Systems, Maximum Control Technologies, National Instruments, OPUS Consulting, Pepperl+Fuchs, Phoenix Contact, Profibus Nutzerorganisation, R. Stahl, RuggedCom, Saudi Aramco, Shell Global Solutions, Siemens, Smar, Softing, Turck, Westlock Controls, Wi-Fi Sensors, Inc., and Yokogawa.

Edited by Peter Welander, pwelander(at)cfemedia.com

www.fieldbus.org



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.