Industrial-grade computer for oil and gas industries

Moxa's EXPC-1319 hazardous location panel computer is designed for hazardous conditions in the oil and gas industries and has an anti-glare, anti-scratch LCD panel that is visible in direct sunlight.

07/25/2013


Moxa's EXPC-1319 hazardous location panel computer is designed for hazardous conditions in the oil and gas industries and has an anti-glare, anti-scratch LCD panel that is visible in direct sunlight. Courtesy: MoxaMoxa's EXPC-1319 hazardous location panel computer is designed to be used in industrial settings that are potentially hazardous and can withstand extreme temperatures in the oil and gas industries. 

Designed for rugged environments, the EXPC-1319 meets UL Class 1, Div 2 and IEC ATEX Zone 2 hazardous location codes without the need for special measures such as complex and expensive enclosures or additional certification processes. It is qualified for direct installation in hazardous areas worldwide where potentially explosive gases or vapors may be present, such as in petrochemical and chemical processing plants, mining, paint factories or fueling stations. Because these areas are often subject to high humidity, the panels are sealed off to NEMA4X and IP66 ingress standards to protect their sensitive electronics from water ingress, even when they are deployed outdoors. 

In addition, the panels meet T5 temperature requirements by maintaining an operating temperature of 120°C or less (248°F) in ambient temperature of 60°C (140°F). On the other end of the temperature spectrum, the EXPC-1319 is fully functional down to -40°C (-40°F).

Sunlight-readable displays are typically achieved by increasing power to the LED light bars, an approach that produces a brighter display, yet quickly burns out LEDs and significantly reduces overall product life span. The EXPC-1319's anti-glare, anti-scratch LCD panel is visible in direct sunlight.

The EXPC-1319 contains many features that make it suited for use as an operator panel or as a secure system platform for machine control. It comes standard with an Intel 1.8GHz Atom core D525 platform. Depending on preference, the operator can select to use the LCD in either touch-screen or standard mode. 

Serial interfaces, Gigabit LAN ports, USBs, and VGA ports tested for full compliance with flame proofing requirements round out its impressive feature set, along with an expanded set of self-health diagnostics over SNMP for remote monitoring.

Moxa Americas Inc.

www.moxa.com 

- See more Control Engineering HMI and operator interface products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me