IEEE and NFPA collaborate on arc flash initiative

The Institute of Electrical and Electronic Engineers and the National Fire Protection Assn. have undertaken a joint research project to expand the knowledge of electric arc phenomena. Schneider Electric announced a $500,000 contribution to the effort.

03/19/2008


The Institute of Electrical and Electronic Engineers (IEEE) and the National Fire Protection Assn. (NFPA) have undertaken a joint research project to expand the knowledge of electric arc phenomena, and through this research, to enhance worker safety through advances in the codes and standards relating to employee safe work practices. The IEEE/NFPA Arc Flash Collaborative Research Project is all about protecting people.

Areas of research will include the following:

Heat: Burns are the most commonly reported effects of arc flash.

* Pressure: Past incidents and some research have demonstrated that an arcing fault generates a pressure wave. * Sound: Pressure from arcing faults can result in hearing damage to workers.
* Toxicity: The composition of the plasma in an electrical arc and the resultant gases that are released will be analyzed to determine their toxic and corrosive components.
* Medical effects: More needs to be understood about the effects on the human body of various wavelengths of energy in arcing faults.

Research and testing will focus on the following:

* Engineering-based model
* Thermal effects
* Heat transfer and injury statistics
* Hazards other than thermal and electromagnetic
* Electromagnetic hazards
* Impact of enclosures

Schneider Electric North American Operating Division, Palatine, Ill., announced a $500,000 contribution to become a platinum level sponsor of the IEEE and the NFPA Arc Flash Collaborative Research Project. The donation is intended to help expand the knowledge of the electric arc phenomena and enhance worker safety through advances in the codes and standards relating to safe employee work practices.

“Schneider Electric’s contribution toward arc flash research aligns with its commitment to improving electrical standards and ongoing initiatives to protect worker safety,” said Jim Pauley, vice president, industry and government relations for Schneider Electric. “We believe this project will produce the data necessary to further our understanding of the arc flash phenomena, which will help us design safer components and provide better guidelines for safely maintaining electrical equipment.”

An arc flash is an electric current that is passed through air when insulation or isolation between electrified conductors is no longer sufficient to withstand the applied voltage. The flash is immediate, and the results can cause severe injury. According to IEEE research, more than 2,000 times per year, workers are admitted to burn centers for treatment of extended injuries caused by arc flash.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me