IEEE 1588 PCI interface for distributed synchronization

Engineers now can use the new, National Instruments PCI-1588 interface to synchronize clocks and events on multiple distributed devices with sub-microsecond precision using the IEEE 1588 precision time protocol (PTP), the company says. The new interface can be used to develop synchronized data acquisition systems and to synchronize IEEE 1588-capable industrial control and t...

11/01/2005


Engineers now can use the new, National Instruments PCI-1588 interface to synchronize clocks and events on multiple distributed devices with sub-microsecond precision using the IEEE 1588 precision time protocol (PTP), the company says.

The new interface can be used to develop synchronized data acquisition systems and to synchronize IEEE 1588-capable industrial control and test and measurement devices, including future Class A and B LXI devices, the company says. The NI PCI-1588 interface is part of the NI family of synchronization technologies that includes sub-nanosecond PXI backplane synchronization, multi-chassis timing interfaces, and standardized software libraries.

IEEE 1588 PTP, approved in 2002, provides a standard method to synchronize devices on a network with sub-microsecond precision. The protocol synchronizes local clocks to a master clock ensuring that triggers, events and timestamps in all devices use the same time base. IEEE 1588 is optimized for well-defined distributed systems, minimal use of network bandwidth and low processing overhead. The standard has gained acceptance in the industrial automation market, NI says, and is now expanding into the test and measurement and communications markets.

Engineers can use the interface's PTP timestamps to correlate events distributed across an Ethernet network with greater precision and accuracy than available with previous industry standards, NI says. The interface uses RJ-45 Ethernet cabling and can operate as a master or slave clock module. With an onboard FPGA (field-programmable gate arrays), engineers can adjust the frequency and phase of an onboard IEEE 1588 system timer for time-stamping Ethernet packets.

For instance, adjusting the clock frequency to match other clock frequencies improves skew and adjusting the phase improves local PLL clocks and triggers, NI says; it also offers three general-purpose I/O pins and a RTSI bus connection for synchronization with traditional instruments or PLCs and other PCI plug-in devices, respectively. For example, engineers can use the new interface to create a geographically distributed data acquisition system with Ethernet while synchronizing clocks and timestamps to within 200 ns.





Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me