HVAC: Cooling systems

HVAC systems consume 25% to 30% of the energy in a typical commercial building; functionally intensive buildings with controlled environments and large process loads can consume more than this.

05/24/2016

Flash is required!

HVAC systems consume 25% to 30% of the energy in a typical commercial building; functionally intensive buildings (industrial facilities, laboratory buildings, hospitals, data centers, etc.) with controlled environments and large process loads can consume more than this. Generally, 50% of the HVAC energy is used for cooling purposes. Providing cooling comfort and energy efficiency in nonresidential buildings is an ongoing challenge for mechanical engineers. Emphasis on building performance and adoption of energy-efficient building codes is increasing. Designs are based on a host of variables beyond space type and understood loads including operating costs, first cost, lifecycle cost, and measurement and verification (M&V) requirements.

Demand for historically typical cooling technologies, such as variable-air-volume (VAV) and water-cooled chillers, is giving way to a variety of systems, such as displacement ventilation, geo-exchange, simultaneous heating/cooling systems, variable refrigerant flow (VRF), passive design, chilled beams, dedicated outdoor air systems, and evaporative cooling.

Learning Objectives:

  • Explain the applicable codes and standards: ASHRAE Standard 90.1: Energy Standard for Buildings Except Low-Rise Residential Buildings, California Title 24, ASHRAE Standard 189.1-2014, Standard for the Design of High-Performance Green Buildings, and International Energy Conservation Code (IECC).
  • Acquire a basic understanding of the various cooling technologies and systems, with an emphasis on comparative efficiency.
  • Analyze the pros and cons of cooling technologies for various building applications.
  • Compare a variety of systems via case studies and engineering projects.

Presenters:

Rodney V. Oathout, PE, CEM, LEED AP, Principal, Regional Engineering Leader, DLR Group, Overland Park, Kan.

Jason Atkisson, PE, HBDP, Project Manager, Affiliated Engineers Inc., Madison, Wis.

Moderator: Jack Smith, Content Manager, Consulting-Specifying Engineer, CFE Media



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me