HUG: Myth of air gaps

In case anyone was wondering, air gaps don’t exist.

06/29/2012


ISS SourceIn case anyone was wondering, air gaps don’t exist.

They may have at one time, but in today’s modern manufacturing automation environment, they are not viable. An air gap is a physical gap between a network in the enterprise and a control system where digital information cannot cross that line. Yes, vendors and experts talk about air gaps as being a supreme security measure, but if you listened to Eric Byres, chief technology officer and vice president of Tofino Security, during his session entitled “Air Gaps and Unicorns: Do they really Exist?” at Honeywell Users Group (HUG) 2012 in Phoenix, Ariz., a super worm, like Stuxnet, didn’t even care if there was an air gap or not. It had quite a few different attack vectors and it knew how to use them.

“Stuxnet was assuming there was always another pathway in,” Byres said. “Stuxnet played on the human nature of control systems.”

If everyone is fine with the idea an air gap does not really play into the security equation, then the next step is to understand what you really have to protect and then work on a plan that involves solid technology and also fit in the human factor.

“If you want security to work, you have to have it work with the way a human works,” Byres said. “If you design security that runs counter to human nature, then that will be a design flaw.”
Some of the areas Byres said a user should do are:

  • Manage all flows into the industrial control system (ICS)
  • Manage all flows out of the ICS
  • Subdivide the ICS system employing the zones and conduits approach
  • Detect unusual behaviors on the ICS system
  • Don’t focus on protecting your system, focus on knowing your system.

One of the areas Byres talks about frequently is companies should not get caught up in the hype of the latest huge potential attack, but rather understand what you really have to protect.

“Have strategies for looking at all pathways,” he said. “Always protect the crown jewels. Start with what really matters.”

One of the ways to protect those key assets is to understand the system.

“Control systems are usually pretty steady. Knowing that, you can really find out and understand when there is some anomaly on the system. That is something to look at.”

There is no one way to protect systems, instead there is a multitude of options a user must employ to keep the system up and running.

“You have to remember air gaps are a dangerous illusion,” Byres said. “Defense in depth is the only real defense.”



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me