High voltage instrument for semiconductors

Keithley Instruments' Model 2657A High Power System Sourcemeter is designed to source up to five times as much power to a device under test as the nearest competitive system, at significantly lower cost, the company said.

04/04/2012


Keithley Instruments' Model 2657A High Power System Sourcemeter is designed to broaden the range of power semiconductor devices and materials. Courtesy: KeithleyKeithley Instruments, Inc. introduce their Model 2657A High Power System SourceMeter instrument. The Model 2657A adds high voltage to the company’s Series 2600A System SourceMeter family of precision source measurement units. Together, these instruments allow an even broader range of power semiconductor devices and materials. A built-in 3,000 V, 180 W source allows the Model 2657A to source up to five times as much power to a device under test as the nearest competitive system, at significantly lower cost. The precision, high speed 6-1/2-digit measurement engine built into the Model 2657A enables 1fA (femtoamp) current measurement resolution to support the low-leakage requirements of next-generation power semiconductor devices.

The Model 2657A is optimized for high voltage applications such as testing power semiconductor devices, including diodes, FETs, and IGBTs, as well as characterizing newer materials such as gallium nitride (GaN), silicon carbide (SiC), and other compound semiconductor materials and devices. It is also useful for characterizing high speed transients and performing breakdown and leakage tests on a variety of electronic devices at up to 3,000V.

The Model 2657A also offers a flexible, four-quadrant voltage and current source/load coupled with precision voltage and current meters. It combines the functionality of multiple instruments in a single full-rack enclosure: semiconductor characterization instrument, precision power supply, true current source, 6-1/2-digit DMM, arbitrary waveform generator, voltage or current pulse generator, electronic load, and trigger controller, and is fully expandable into a multi-channel, tightly synchronized system via Keithley’s TSP-Link technology. The Model 2657A can source or sink up to 180W of DC power (±3,000V@20mA, ±1500V@120mA). The Model 2657A also offers 1fA resolution, allowing it to make fast, accurate sub-picoamp measurements even when sourcing up to 3000V.

Keithley Instruments, Inc.

www.keithley.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.