High-performance medical and educational building design: HVAC

The design of high-performance medical and educational projects are challenging and need to meet specific standards, codes, and trends. There can be unique HVAC system requirements for high-performance buildings.

06/30/2016


Joseph A. D’Alù, PE, LEED AP, CEM, Division Manager, RMF Engineering,Charlottesville, Va. Courtesy: RMF EngineeringTG Davallou, LEED AP, Partner, Alfa Tech Consulting Engineers, San Francisco. Courtesy: Alfa Tech Consulting EngineersSean Donohue, PE, LEED AP, Director, Colorado Springs, Jensen Hughes, Colorado Springs, Colo. Courtesy: Jensen HughesAnthony B. Preteroti, Associate Vice President, CannonDesign, Grand Island, N.Y. Courtesy: CannonDesignTeresa Rainey, PE, LEED Fellow, Director of High-Performance Design, EYP Architecture & Engineering, Washington, D.C. Courtesy: EYP Architecture & Engineering

Respondents

Joseph A. D'Alù, PE, LEED AP, CEM, Division Manager, RMF Engineering, Charlottesville, Va.

TG Davallou, LEED AP, Partner, Alfa Tech Consulting Engineers, San Francisco

Sean Donohue, PE, LEED AP, Director, Colorado Springs, Jensen Hughes, Colorado Springs, Colo.

Anthony B. Preteroti, Associate Vice President, CannonDesign, Grand Island, N.Y.

Teresa Rainey, PE, LEED Fellow, Director of High-Performance Design, EYP Architecture & Engineering, Washington, D.C.


 

CSE: Have you specified distinctive HVAC systems on any high-performance campus projects?

Davallou: Yes, for all of the College of Marin projects including the main building; math and science buildings have geothermal HVAC systems.

CSE: What unique HVAC requirements do high-performance campus projects have that you wouldn't encounter in other projects?

Davallou: Geothermal systems will require a detailed well-test analysis and the water department's approval. For example, for the Mission College project's main building, we had to change the vertical-loop design to horizontal-loop during the construction administration because of leakage, which was not acceptable by the water department.

CSE: When retrofitting existing buildings for such projects, what challenges have you faced and how have you overcome them?

Davallou: We've seen space issues for thermal storage and geothermal. For Soka University, we looked at a void space near the central plant to locate the chilled-water thermal storage tanks.

 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me