High output accelerometer for machinery health monitoring

The 786-500-D2 accelerometer by Meggitt is designed for condition monitoring for rotating equipment and can be used in hazardous areas because of its Class I Div 2/Zone 2 certification.

01/25/2012


The 786-500-D2 accelerometer by Meggitt is designed for condition monitoring for rotating equipment and can be used in hazardous areas because of its Class I Div 2/Zone 2 certification. Courtesy: MeggittMeggitt's 786-500-D2 is a new high output accelerometer for machinery health monitoring. The 786-500-D2 accelerometer carries CSA approvals for Class I Div 2/Zone 2 areas and has a high 500 mV/g output sensitivity and a broadband frequency response for multi-use applications.

The 786-500-D2 accelerometer is well suited for condition monitoring of a variety of rotating equipment including those in hazardous areas. Slow speed applications, such as wind turbine generators will benefit from the strong 500 mV/g output of the 786-500-D2 because it overcomes data collector noise that can mask peaks at low frequencies. In high speed applications, such as machine tool spindles or gear mesh frequencies the sensor’s higher sensitivity results in better detection of low level vibrations.

The accelerometer houses a 500 mV/g sensing element with a tight 5% sensitivity tolerance coupled with a ± 3 dB frequency response range that covers 0.2 to 14,000 Hz. As a multi purpose sensor with a full scale acceleration range of 10 g and an excellent broadband noise floor of 250 μg, the 786-500-D2 is ideal for applications where both ends of the machine spectrum need to be monitored simultaneously.

Class I Div 2/Zone 2 certification means the 786-500-D2 can be used in higher risk areas, those defined as areas where hazardous gas, vapors or mist would only be present under abnormal conditions. While not as stringent as Division 1/Zone 1 certifications, this CSA certified unit can be safely used on motors, pumps, fans and other process equipment located in hazardous areas. Since no safety barriers are required in Division 2/Zone 2 areas, installation of the sensor is simplified.

Meggitt PLC

www.meggitt.com 

- Edited by Chris Vavra, Control Engineering, www.controleng.com

controleng.com/sensors



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.