High-frequency analog IO modules

High-frequency Snap-Airate-HFi rate input and Snap-AOD-29-HFi pulse-width modulation (PWM) modules by Opto 22 support testing, simulation, and other high-speed applications.

10/15/2013


High-frequency SNAP-AIRATE-HFi rate input and SNAP-AOD-29-HFi pulse-width modulation (PWM) modules by Opto 22 support testing, simulation, and other high-speed applications. Courtesy: Opto 22Opto 22 introduced two new high-frequency analog Snap I/O modules, the Snap-Airate-HFi rate-input module and the Snap-AOD-29-HFi module. The Opto 22 Snap-AOD-29-HFi module has pulse-width modulation (PWM) and time-proportional output (TPO). These modules are designed for test engineers, technicians, and others working with high-speed machinery, equipment test beds, and other applications that monitor high-frequency analog signals and rapidly switch digital outputs in response to a changing analog value. Both modules are used with Opto 22’s Snap PAC System, which includes programmable automation controllers (PACs) and Ethernet-based I/O systems.

The analog input module connects to TTL, CMOS, and open-collector outputs, and is typically used for high-speed (up to 500 kHz) pulse scanning. The module has two isolated channels, each of which can be configured for a 0.1-second measurement interval with an input range of 20 Hz to 500 kHz, or a 1-second measurement interval with an input range of 2 Hz to 500 kHz. For each channel, 9 V dc is provided internally for devices with open-collector outputs, making it unnecessary to provide a pull-up voltage supply.

The analog output module sends pulse-width modulated outputs to high-frequency transducers and can be used, for example, with test bed applications that simulate tachometer outputs. Each of the module’s two optically isolated channels can switch 100 mA of load current ranging from 2.5 V dc to 24 V dc (supplied externally), over a period range of 10 microseconds to 64.25 seconds (0-100 kHz).

Both modules are optically isolated from the equipment and devices they connect to, as well as from other analog, digital, and serial modules on a shared I/O rack.

Opto 22

www.opto22.com 

- See more Control Engineering I/O system and module products.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me