Greenhouse gas flow meter for process, plant flue gas applications

A mass flow meter designed to monitor greenhouse gases can help users in chemical, food processing, petroleum refining, pharmaceutical, electric power generation, and other plants be in compliance with the EPA emission requirements.

09/15/2010


Process and plant engineers who are concerned about the U.S. EPA’s greenhouse gas  monitoring requirements will find the ST51 GHG mass flow meter from Fluid Components International (FCI) provides just what they need. The ST51 features a no-moving-parts design that’s non-clogging, and it operates over a wide flow range with low-flow sensitivity. It’s packaged in an explosion-proof transmitter, and the calibration is matched to the user’s actual gas composition and installation conditions. Flue gases, the mixed-composition hydrocarbon greenhouse gases that are the by-product of an industrial plant combustion process, can include nitrogen, carbon dioxide, oxygen, water vapor, sulfur oxides, nitrogen oxide, carbon monoxide, particulates, ozone, and methane. 

The ST5 features a thermal mass, insertion-style flow element with flow accuracy to ±1% of reading over a broad flow range from 0.3 to 400 SFPS (0.08 to 122 MPS), and repeatability of ±0.5% of reading. The flow element is available for use in line sizes from 2 to 24 in. (51 to 610 mm). It operates over a wide turndown range of 100:1 and at temperatures from 0 to 250 °F (-18 to 121 °C). It withstands pressures up to 500 psig (34 bar).

The unit's robust thermal mass flow sensing element has no moving parts and no orifices to clog or foul, allowing it to attain virtually maintenance-free service in wet, dirty biogas applications. The flow element is constructed with a 316L stainless steel body and Hastelloy C-22 thermowell sensors to resist corrosion. It includes built-in temperature compensation circuitry for accurate, repeatable measurement as temperatures rise and fall seasonally.

Dual 4-20 mA analog outputs are user-assignable to flow rate and/or temperature, and there is a 0-1 kHz pulse output for totalized flow. The transmitter’s digital communications include an RS-232C port, and with units that have the digital display option there is a wireless IR link for PDA use. An optional integral digital display features a two-line, 16-character LCD screen that can be rotated in 90° increments for optimum viewing. The LCD screen’s top line is assigned to flow rate, and the bottom line is user-assignable for temperature readings or totalized flow.

www.fluidcomponents.com

Fluid Components International

- Also from Control Engineering:

Gas flowmeter for chlorine water disinfection systems

Mass flowmeter optimized for biofuels applications

Video Demonstration: Thermal Mass Flow Sensing Technnology


- Edited by Renee R. Bassett for Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.