Generator set

Provide island mode operational capability with two G3520C natural gas generator sets. The gensets are offered in 60- and 50-Hz versions that are driven by an electronically controlled, lean-burn gaseous-fueled reciprocating Caterpillar engine. The sets have an ISO electrical efficiency of 38.4% at 60 Hz and 40.

06/01/2008


Provide island mode operational capability with two G3520C natural gas generator sets. The gensets are offered in 60- and 50-Hz versions that are driven by an electronically controlled, lean-burn gaseous-fueled reciprocating Caterpillar engine. The sets have an ISO electrical efficiency of 38.4% at 60 Hz and 40.4% at 50 Hz. The sets operate at 60 Hz/1,800 rpm with a continuous rating of 2,055 ekW, or at 50 Hz/1,500 rpm with a continuous rating of 1,966 ekW. The sets have a standard NOx emissions rating of 1g/bhp-hr at 60 Hz and 500mg/NM3 at 50 Hz, with performance of 0.5 g/bhphr at 60 Hz and 250mg/NM3 at 50 Hz available through a 54 C separate circuit after-cooler system that can be used with a conventional cooling system arrangement.

Caterpillar Circle 454





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me