Fusion dedicated outside air system

PremiSys fusion dedicated outside air system is is a split-system consisting of a variable refrigerant flow outdoor unit and an air handler for acclimatizing outside air for commercial buildings.

05/13/2016


PremiSys fusion dedicated outside air system is is a split-system consisting of a variable refrigerant flow outdoor unit and an air handler for acclimatizing outside air for commercial buildings. Courtesy: Mitsubishi ElectricMitsubishi Electric Cooling & Heating's PremiSys fusion dedicated outside air system is is a split-system consisting of a variable refrigerant flow outdoor unit and an air handler for acclimatizing outside air for commercial buildings. The two models, MPF-1 and MPF-2 are designed to handle outside air with energy recovery and are pre-engineered to provide semi-custom flexibility. Heating options include modulating gas heat, electric, and hot water coils. The system uses of an inventer-driven compressor that allows matching the conditions of the targeted temperature and outside air, which results in energy reduction. Other features include ability for distributed load on the roof, humidity control, and cooling capacity of 5 to 20 tons.

Mitsubishi Electric Cooling & Heating

www.mehvac.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me