Fuel moisture sensor for biomass plants

Emerson Process Management has integrated a fuel moisture sensor into their Ovation control system to allow continuous monitoring of biomass feedstock for moisture content.

07/01/2013


Emerson Process Management now offers an integrated solution that enables biomass-fuelled power plants to continually monitor feedstock moisture content and adjust the combustion process for better efficiency. The solution, which combines a biomass fuel moisture sensor with Emerson’s Ovation expert control system, can help reduce maintenance costs as well as boost net yearly MWh production.

Biomass fuels vary considerably in their energy content. Fuel that has high moisture content will generate less heat and will have a significant effect on energy recovery in steam generators. The traditional method of controlling the combustion process is by monitoring the flue gases and adjusting the combustion air to give the best efficiency. However, rapidly changing fuel quality and boiler characteristics can make maintaining optimum conditions difficult.

Emerson’s new integrated solution continuously monitors fuel for moisture content as it is being fed into the combustion chamber. The Ovation system uses this data to adjust the combustion air to match the characteristics of the fuel based on the master set-point output (MWe steam or pressure), boiler response and the thermal cycle overall. This enables the plant to react much more quickly to changes in fuel moisture content, maximizing combustion efficiency.

Suitable for new or existing installations, the system comprises a small skid that takes biomass fuel from the transport system, measures its moisture content using microwave technology and returns it to the transport system. 

The moisture sensor is connected via Ethernet to the Ovation system, providing an input to the boiler and thermal-cycle control logic. The data provided is analyzed to provide fast and accurate information on the temperature and moisture content of the feedstock.

Monitoring and controlling combustion air can dramatically influence profits and costs of boiler operations. Excess oxygen does nothing to improve combustion. Instead, it actually serves to reduce boiler efficiency by absorbing heat that could be used in steam production. Ovation helps to modulate the amount of air in the system to provide the exact amount of air that the system needs, ensuring efficient combustion. 

Emerson Process Management

www.emersonprocess.com 

- See more Control Engineering sensor products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me