From packaging to tuning to visualization

Applied Automation covers aspects of the bagging process, PID tuning, and HMI system standardization in the December 2013 issue.

12/27/2013


The cover story in this issue of Applied Automation talks about packaging specifically, the bagging process. Industrial bag packaging machines are designed to fill plastic and paper bags with dry bulk products, such as powders, granules, or flakes. The author points out that efficient, effective, and accurate bagging is a direct result of optimizing the relationship between the bagging machine, the bag, and the product. Finding the right combination of these three factors should be obvious. However, if one of them changes, one-or sometimes both-of the others may need to change as well.

This issue also includes an article about PID tuning—a topic frequently covered by Applied Automation, Control Engineering, and Plant Engineering. My first exposure to PID tuning was a vintage ISA training film (not a video; the film predated even VCRs) about tuning pneumatic controls. The concepts are the same. However, the ways they are applied continue to advance. The author provides PID tuning advice, explains different tuning processes, and explains the theory behind modeling processes. Automatic tuning software can greatly simplify the PID tuning process in many cases. Although automatic software has been around for more than 30 years in one form or another, it continues to advance as well.

The third article revisits HMIs—another topic that continues to be popular among automation and control professionals. In this article, the author advocates HMI system standardization, which involves using standard graphics, naming conventions, and application design concepts to provide a consistent look and feel among multiple HMIs throughout the plant. The author contends that HMI standardization can increase productivity, simplify operation, and reduce operating costs.

Check out the links to the stories below.

This article appears in the Applied Automation supplement for Control Engineering and Plant Engineering



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me