SEARCH Archives
Loading
Sponsored by:

Flow computer handles critical oil mass and volume calculations

New meter prover interface feature from ProSoft Technology performs sophisticated functions on Rockwell’s ControlLogix platform.

04/29/2011


New meter prover interface feature from ProSoft Technology performs sophisticated functions on Rockwell’s ControlLogix platform.ProSoft Technology has announced version 2.07 of its Liquid and Gas Flow Computer for the Rockwell Automation ControlLogix platform (MVI56-AFC). In oil applications, crude is extracted and transported through pipelines that often run hundreds of miles through varying climates, temperatures, and altitudes. As these elements vary, so do the properties of the petroleum, necessitating flow computers to validate the precise quantity of product at designated points along the pipeline. Precise flow calculations require accurate data from properly calibrated flow meters. Meter provers help validate proper flow meter operation.

The ProSoft Technology flow computer calculates a meter factor based on constants and variables affecting flow rates, accumulated volumes, and accumulated mass of the liquid petroleum product flowing through a prover with known volume. With the new meter-proving feature, the module is now able to communicate meter-prover test results directly to the control processor and SCADA control system. Operation of the prover-interface feature can be performed manually, completely automated, scheduled, triggered by events, or operator intervention.

The prover interface feature supports these prover types:

• Unidirectional pipe prover;
• Bidirectional pipe prover;
• Compact prover; and
• Master meter prover.

The module resides directly in the ControlLogix chassis, acting as an add-on co-processor, dedicated to calculating flow measurements without burdening the PLC with complicated flow algorithms. Additional features include:

• Multiple, independently-configuratble meter streams: The module supports up to 16 meter runs with four streams per meter and allows the PLC/PAC to switch the active stream via program logic. Each of the channels are individually configurable to calculate hydrocarbon gas or liquid flows.

• High precision analysis for multiple streams: Fractional components of hydrocarbon gases may be entered as floating-point values with precision of seven or more significant digits.

• Completely automated control: The module is programmed, managed, and monitored by the PLC or SCADA system.

• Complies with AGA 3, 7, 8, and MPMS Chapters 11 and 12.2 measurement standards.

• Event log lockout security: Prevents overwriting past events which have not yet been downloaded and archived in some off-module system.

• Modbus dictionary: This index allows users to locate the Modbus address of needed data.

www.prosoft-technology.com

Visit the Control Engineering Process Control channel.

Edited by Peter Welander, pwelander(at)cfemedia.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.