Readers provide feedback on Control Engineering articles on advance motor designs and on gain scheduling. See links, comments, below.

02/16/2011


Articles on advanced motor technologies and on gain scheduling drew reader feedback recently. See comments and links to articles, below.

FEEDBACK: Gain scheduling

Gain scheduling tutorial, Control Engineering Back to BasicsConcerning your article titled “How gain scheduling works” on page 56 of the January 2011 edition of Control Engineering, I have a suggestion.

Instead of implementing gains scheduling, why not linearize the process feedback to units of volume?  If you use the water level to calculate the current volume of water in the tank, the need for gains scheduling goes away.  While the gains of the PID are no longer scheduled, the effective gain of the system still changes – so the engineer would have to be careful to tune his PID so that it was still stable in the region where the ratio of tank level to volume was the highest (in this case, the mid-point of the tank).  However I would argue that the overall system will be easier to tune, take less time to tune, and be simpler.  Plus it allows you to determine the percentage of the tank’s capacity, which will likely be more useful to the operator or controls software than percent of non-linear level.

John Blystone, Instrumentation & Controls Department Supervisor
Louis Perry & Associates Inc.
www.louisperry.com

FEEDBACK: New motor technologies

South Korea’s Electric Research Institute (KERI) has been building various transverse flux motors for more than 10 years.Great article from Dan Jones on new motor technology. Great to get this by email. [This article was included in the Feb. 10 Control Engineering Machine Control monthly eNewsletter. Others may subscribe to eNewsletters at www.controleng.com/subscribe; browse other motor developments at www.controleng.com/new-products/motors-and-drives.html.]

The article cuts across many industries and should be followed up with some details on the individual companies that were cited. [See additional links added below.] I think there is a lot of interest because motors are so widely used and so poorly understood. The connection to the electric car is also a popular theme.

Thanks for a great job. 

Steve Meyer, CEO/Senior Consultant

Solid Tech Inc.

www.solidtechinc.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me