Extended no-stop couplings for joining black iron pipe

Extended no-stop coupling options for the MegaPress and MegaPressG systems use cold press connections for pipe installation.

07/21/2016


Extended no-stop coupling options for the MegaPress and MegaPressG systems use cold press connections for pipe installation. Courtesy: ViegaViega's extended no-stop coupling options for the MegaPress and MegaPressG systems are designed for joining schedule 5 to schedule 40 black iron pipe in sizes 1/2 to 2 in. The Viega MegaPress system uses cold press connections for pipe installation. The system is suited for hydronic heat, chilled water, compressed air, fire sprinkler systems, low-pressure steam, and vacuum lines. The fittings include elbows, couplings, reducers, reducing tees, threaded adapters, caps, flanges, and unions made with a stainless steel grip ring with an EPDM sealing element or HNBR. MegaPress system is UL, FM, and ASME B31 compliant for fire sprinkler, pressure, and boiler piping applications. MegaPressG fittings are CSA LC4 compliant for fuel gas and oil applications.

Viega

www.viega.us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me