Explosion-proof smoke detectors

The Det-Tronics SmokeWatch is applicable to industrial HVAC duct-monitoring.

08/28/2017


The unit's photoelectric sensor ensures accurate smoke detection with less potential for false alarms than other smoke detection technologies. Courtesy: Det-Tronics

The Det-Tronics SmokeWatch U5015 uses advanced photoelectric smoke detection technology not generally available in an explosion-proof housing. The detector is rated for Class 1 Division 1, 2 and Zone 1 environments found in industrial applications. Used with the Q5016 Duct Mount Accessory, the detector can be installed on ductwork to meet NFPA 90A requirements for air handler units of more than 2,000 cfm.

The unit's photoelectric sensor ensures accurate smoke detection with less potential for false alarms than other smoke detection technologies. The detector's design operates effectively in both smoldering and rapidly growing fires.

Approved for both HVAC ductwork and area installation, the SmokeWatch U5015 unit integrates with fire alarm systems for evacuation alerts. When connected to process controls, the SmokeWatch U5015 can be used to initiate smoke-control procedures such as fan shutdown and fire damper operation. The detector carries FM 3230 approval for detection performance and meets NFPA 72 and 92 equipment requirements.

Det-Tronics

www.det-tronics.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me