Explosion-proof LED light fixture

The 50 W hazardous area LED light fixture is a fully integrated unit designed for recessed panel mounting.

12/06/2016


The 50 watt hazardous area LED light fixture is a fully integrated unit designed for recessed panel mounting. Courtesy: Larson ElectrionicsThe HALD-24-1X50 LED is designed to provide operators with an alternative to traditional hazardous location luminaires. This explosion-proof fixture is a 2x2 Class 1 Division 1 lay-in LED light panel with a T5 temperature rating, and it is a fully integrated LED unit. The LED assembly is protected by an aluminum frame and a hinged 3/16-in. thick poly-carbonate door that provides direct front access to the internal components. The lamp housing is designed for recessed mounting, features multiple LED drivers, and provides 5,834 lumens of light while drawing only 50 W of power. The housing is specially designed to dissipate heat and requires a mounting hole to be made in booth panels capable of accommodating the fixture housing to provide the maximum amount of space in paint spray booth enclosures. This light is multi-voltage capable and can be operated at 100- to 277-Vac without any need for a special ballast.

Larson Electronics

www.larsonelectronics.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me