SEARCH Archives
Loading
Sponsored by:

Exhaust fan line

Greenheck’s Vektor-HS with SAVVE technology is designed to reduce energy consumption and can automatically adjust the nozzle discharge area to maintain a constant and safe velocity.

11/27/2012


The Vektor-HS with SAVVE technology is designed to reduce energy consumption and can automatically adjust the nozzle discharge area to maintain a constant and safe velocity. Courtesy: GreenheckGreenheck’s Vektor-HS with SAVVE technology reduces fan energy consumption and operating costs in variable volume or demand-based laboratory ventilation systems. Sure-Aire Variable Volume Exhaust or SAVVE technology incorporates the Sure-Aire noninvasive flow monitoring system that measures pressure drop across a fan’s inlet venturi. As airflow through the fan varies, SAVVE technology automatically adjusts the nozzle discharge area to maintain a constant and safe discharge velocity (minimum 3,000 ft/min per ANSI Z9.5) while energy consumption of the exhaust fan is reduced regardless of the laboratory exhaust airflow. Benefits include reduced fan energy, reduced horsepower, and lower sound levels while maintaining proper pressurization of occupied spaces. 

Greenheck 

www.greenheck.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.