Ethernet gateway makes PLCs 'future proof’

Moxa's MGate EIP3000 series products provide 1 or 2-port DF1 to EtherNet/IP protocol conversion for users who need to connect Allen-Bradley PLCs to an EtherNet/IP network. This is an October Control Engineering North American edition Product Exclusive.

10/01/2009


 

Moxa MGate EIP3000 gateways provide 1- or 2-port DF1-to-EtherNet/IP protocol conversion to connect Allen-Bradley PLCs to an EtherNet/IP network.

Moxa MGate EIP3000 gateways provide 1- or 2-port DF1-to-EtherNet/IP protocol conversion to connect Allen-Bradley PLCs to an EtherNet/IP network.

Moxa’s MGate EIP3000 series products provide 1 or 2-port DF1 to EtherNet/IP protocol conversion for users who need to connect Allen Bradley PLCs to an EtherNet/IP network. The EIP3000 series products can be used to provide the PLCs with remote maintenance capability. By supporting PCCC objects on CIP, the MGate EIP3000 can communicate seamlessly with Rockwell Ethernet devices. The gateway products support up to eight EtherNet/IP clients and eight EtherNet/IP servers simultaneously, and each client can send up to 16 requests at one time. Moxa provides a user-friendly Microsoft Windows utility with multiple language support for use with MGate products. The utility also provides traffic monitoring for EtherNet/IP and DF1 protocols. Each MGate EIP3000 gateway supports virtual serial ports. A remote PC uses a Moxa-provided Real COM or TTY driver to connect to the gateways’s virtual serial port. RSLinx and SCADA systems can use the virtual COM port to communicate with a PLC through the gateway. The virtual serial port function gives RSLinx or SCADA systems the ability to connect to multiple DF1 PLCs through an EIP3000 protocol gateway as well as EtherNet/IP devices. When using termination resistors to prevent serial signal reflection, it is important to set the pull high/low resistors correctly so that the electrical signal is not corrupted. Since no set of resistor values is universally compatible with all environments, this gateway has DIP switches for setting the termination and pull high/lo resistor values.

www.moxa.com

Moxa





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me