Emergency safety button with illuminated base
Banner Engineering's 30mm Mount Illuminated Emergency Stop Pushbutton is IP65-rated and is designed for emergency stop safety applications.
The Banner Engineering 30 mm Mount Illuminated Emergency Stop Pushbutton combines status indication and safety. With bright, highly-visible illumination, the new E-Stop is ideal for diverse emergency stop safety applications, helping to provide users with enhanced safety and productivity on the manufacturing floor, the company said.
Featuring Banner EZ-Light logic, the 30 mm Mount E-Stop pushbuttons provide an illuminated yellow base when the button is armed and the machine is enabled to run or is running. When the button is pushed, the yellow illumination turns to a flashing red indication to alert operators of an emergency stop condition. Users can easily reset only the pushed button or buttons, readying the device efficiently with minimal downtime. The yellow illumination can also turn to a steady red indication when a stop condition exists by applying an external signal via the M12 QD connector. To meet diverse application requirements, the e-stops are available with two-color yellow and red lighting, red lighting or a non-illuminated black base.
Offering a IP65-rated design and 30 mm mounting base, the e-stop pushbuttons allow convenient installation with no assembly, individual wiring or additional enclosure required. For applications requiring a series of e-stops, multiple buttons can be interfaced and series connected with CSS Series Hookup Cordsets. Flush (surface) mount models are also available with standard, illuminated, lockable and illuminated lockable pushbuttons. Also, the E-Stop button has “Safe Break Action” to ensure the safety contacts will open if the contact block is separated from the actuator.
Banner Engineering
- Edited by Chris Vavra, Control Engineering, www.controleng.com
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.