Embedded PC has Profinet interface

The CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and is suitable as a stand-alone controller and can be used as a tie-in with larger Profinet systems.

09/13/2013


The CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and is suitable as a stand-alone controller and can be used as a tie-in with larger Profinet systems. Courtesy: Beckhoff AutomationThe CX8093 Embedded PC from Beckhoff Automation is equipped with a Profinet interface and the option to integrate a virtual device. The DIN rail mounted CX8093 is equipped with a 400 MHz ARM9 CPU for ultra compact PC-based control.

The CX8093 is suitable as a stand-alone controller for a wide range of industrial applications in smaller sized machines or systems and can be used as a tie-in to larger Profinet systems. The CX8093 Embedded PC from Beckhoff is equipped with a Profinet RT device interface designed as a 2-port switch for daisy-chain cabling. A special feature is the added functionality of a virtual device which can be used to double the process data size or to connect a second controller.

When the optional virtual device (slave interface) is activated, the CX8093 Embedded PC behaves like two Profinet devices. Accordingly, the CX8093 can process twice the amount of Profinet process data. The network name of the two devices can be set via the address switch or in software using TwinCAT System Manager from Beckhoff. The IP settings are allocated by the Profinet controller.

A further benefit of the virtual device is the ability to communicate with a second Profinet controller, which is a simple way to increase system availability. On the one hand, the CX8093 (as a local controller) can verify the two incoming master signals by means of a plausibility check to monitor the function of the cabling, for example. On the other hand, failure of one of the masters can be detected and the second master can respond accordingly.

The space-saving CX8093 Embedded PC measures only 65 x 100 x 80 mm. It runs Windows CE 6.0 and features a 400 MHz ARM9 CPU, 64 MB RAM and a MicroSD card with up to 4 GB storage capacity. The range of Beckhoff IP 20-rated I/O, including Bus Terminals and EtherCAT Terminals can be connected directly to the CX8093. During start-up, the CX8093 automatically detects which of these I/O systems is connected. Another special feature is a capacitive 1-second UPS that enables persistent data to be saved in the event of a supply voltage failure. The controller is programmed via TwinCAT PLC automation software.

Beckhoff Automation

www.beckhoff.com 

- See more Control Engineering embedded systems products.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me