EEA Consulting Engineers: Thermal Utility and Electrical Masterplan

Generation and distribution project as part of a master plan at an educational facility.

08/14/2014


Engineering firm: EEA Consulting Engineers
2014 MEP Giants rank: 83
Project: Thermal Utility and Electrical Masterplan
Address: Huntsville, Texas, U.S.
Building type: Educational facility,Utilities/public works/transportation
Project type: Other
Engineering services: Electrical/power, HVAC/mechanical, lighting, energy/sustainability, plumbing/piping, and other
Project timeline: 4/16/2012 to 3/27/2013
MEP/FP budget: $194,500

Challenges

The project is a study of the 7,000-ton chilled water, 18,000 MBTU heating water, and electrical systems on campus and is part of a larger master planning project for Sam Houston State University performed by SmithGroupJJR. The following components were included in this study:

  1. Campus thermal utility cooling and heating load analyses
  2. Hydraulic models of the 33-building campus chilled and heating water systems as they are currently installed, as well as models depicting the campus master plan and resulting recommended utility infrastructure upgrades and improvements
  3. Thermal expansion model of the east campus heating water loop replacement
  4. Campus electrical system load analysis, short circuit and coordination study, and harmonic study.

The majority of the new master planned construction was located on two separate ends of campus. This created the challenge of providing new utilities to two new portions of the campus within a short period of time. Existing and new construction in addition to landscaping, known existing utilities, and general constructability were all considered in routing the new utilities throughout the campus. Initial capacity and distribution issues with the campus utility generation systems needed to be addressed in the master plan. Recommended scheduling was needed to identify priorities and coincidences with other planned projects on the campus. The university's desire for general system redundancy, coupled with several high-priority buildings, also needed to be integrated into the utility masterplan. Minimizing both system downtime and interruption to surface traffic were also extremely important considerations.

Solutions

The final master plan for the system maximized usation of existing generation and distribution equipment (both in plants and piping) to allow for phasing of the utility infrastructure upgrade installations. This was to be done in two ways:

  1. Renovation of existing equipment to maximize capacity, and
  2. Connecting to the existing system in strategic locations that would maximize use of the existing piping under normal operating conditions.

The end result was a utility master plan that would provide a robust and redundant generating and distribution system capable of providing reliable utility service to the existing and planned customer buildings far into the future.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me