EC: Yokogawa CW10 Clamp-on Power Meter

Hardware – Handheld test, measurement, calibration: The Yokogawa CW10 Clamp-on Power Meter is capable of measuring up to 600 kW, 600 A, and 1,000 V, and can also measure power factor, harmonics, total harmonic distortion, frequency, and resistance in one portable test instrument. This is a Control Engineering 2012 Engineers’ Choice honorable mention.

11/15/2011


Yokogawa CW10 Clamp-on Power Meter. The Yokogawa CW10 Clamp-on Power Meter is capable of measuring upto 600 kW, 600 A, 1000 V and can also measure power factor, harmonics, total harmonic distortion, frequency, resistance in one portable test instrument. This is a Control Engineering 2012 Engineers' Choice finalist.The Yokogawa CW10 Clamp-on Power Meter combines the basic functionality of a standard clamp on tester, digital multimeter, and power monitor to initially diagnose maintenance and electrical issues before more expensive and sophisticated equipment may be required to analyze the performance of motors, generators, and other power-related equipment. The CW10 is easy to use, easy to carry, and will prove to be the primary diagnostic instrument in a technician's tool kit, according to Yokogawa.

The CW10 allows technicians and maintenance personnel to measure 600 A ac/dc, 1,000 V ac/dc, 600 kW ac/dc, power factor, total harmonic distortion, harmonics from 1st to 25th, resistance, and frequency. Other measurement and diagnostic capabilities include phase rotation, voltage detection, continuity check, diode test, inrush current, and low pass filter. The CW10 possesses a rotary switch and joystick that allows the user to easily select the preferred measurement and diagnostic function. The display is backlit when clamping and contains a 3.5-digit and bar graph display.

The CW10 meets CAT IV 600 V and CAT III 1,000 V safety standards and is CE rated. Standard accessories provided with the unit are one 9-V battery, test leads, a soft case, and an instruction manual. Alligator test leads are also available.

www.yokogawa-usa.com

http://metersandinstruments.yokogawa-usa.com/item/portable-power-monitor-recorder/e-power-monitor-recorder-cw10-clamp-on-power-met-2/cw10-clamp-on-power-meter?

Yokogawa

Return to the list of the 2012 Engineers' Choice honorable mentions.

View the list of the 2012 Engineers' Choice winners.

View the complete list of the 2012 Engineers' Choice finalists.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me