SEARCH Archives
Loading
Sponsored by:

EC: TM18 Photoelectric Sensor

Machine and embedded control – Discrete sensors: The TM18 is a compact photoelectric sensor from Banner Engineering that features metal housing for superior durability and resistance in harsh sensing environments. This is a Control Engineering 2012 Engineers’ Choice honorable mention.

11/17/2011


TM18 Photoelectric Sensor. The Banner Engineering TM18 is a compact photoelectric sensor that features metal housing for superior durability and resistance in harsh sensing environments. This is a Control Engineering 2012 Engineers’ Choice finalist.The TM18 photoelectric sensor from Banner Engineering features a nickel-plated, die-cast zinc metal housing, as well as completely epoxy-encapsulated electronics. Rated IP69K, the TM18 provides superior durability and resistance in harsh sensing environments, especially in high-pressure wash-down applications. With a compact, right-angle shape; an 18mm threaded barrel mount; and integral all-metal M12 quick disconnect, the TM18 sensor fits in tight places and avoids sensor damage during machine assembly, transport, maintenance, and operation.

The TM18 is unique because it goes beyond a compact shape and hygienic design. The mechanically robust sensor is designed for heavy-duty customers with its all-metal, one-piece design. Additionally, it offers users improved immunity to electromagnetic noise and enhanced immunity fluorescent lamps ensuring reliable sensing performance in diverse applications. In addition to a robust housing, the TM18 is also available in visible red-emitter LED models offering opposed, polarized retroreflective, diffuse, and fixed-field (background suppression) modes, allowing it to easily align to the desired target. This extends the sensor’s operating capability, making it ideal for sensing on conveyors in heavy-duty machine settings, automotive machining and production equipment, off-road and outdoor equipment, or in high-traffic areas where the sensor could be bumped or stepped on.

www.bannerengineering.com

www.bannerengineering.com/en-US/products/industry/17/660/Food-Beverage/591/TM18-EZ-BEAM-DC

Banner Engineering

Return to the list of the 2012 Engineers' Choice honorable mentions.

View the list of the 2012 Engineers' Choice winners.

View the complete list of the 2012 Engineers' Choice finalists.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.