EC: L Series Temperature Controller

Machine and embedded control – PLCs: The L Series Temperature Controller from Mitsubishi Electric is intended to reduce energy consumption and improve manufacturing sustainability. This is a Control Engineering 2012 Engineers’ Choice honorable mention.

11/17/2011


L Series Temperature Controller. The L Series Temperature Controller from Mitsubishi Electric is intended to reduce energy consumption and improve manufacturing sustainability. This is a Control Engineering 2012 Engineers’ Choice finalist.Mitsubishi Electric’s L60TC temperature controller performs PID operation to reach the target temperature based on input from an external temperature sensor. Up to four loops of temperature adjustment control can be performed simultaneously in a single module. In addition, loop control can be performed using analog modules in the system; input from an A/D converter module or output to a D/A converter module can be processed. The module controls temperature by outputting the operation result to a heater or others in transistor output. The L60TC4 performs temperature adjustment control automatically when the user simply sets PID constants necessary for PID operation: proportional band (P), integral time (I), derivative time (D), and temperature set value (SV).

No special instructions are necessary to perform PID control. Using the auto-tuning function or self-tuning function enables the PID constants to be set automatically by the L60TC. Complicated PID operational expressions to determine PID constants are not necessary. Temperatures of multiple loops can be adjusted to simultaneously reach the set value of each; temperatures are controlled evenly without any partial heat exaggeration. Designed to directly improve manufacturing operating costs, the L60TC is the first temperature controller with advanced, integrated features to specifically address a reduction in energy consumption. Synchronous Temperature Rise creates a uniform temperature control through the ability to manage multiple loops, eliminating partial thermal expansion and burn-off. Peak Current Control controls the heater’s current flow without the need to synchronize the output timing. 

www.meau.com

www.meau.com/eprise/main/sites/public/Products/Programmable_Logic_Controllers/L_Series/default

Mitsubishi Electric

Return to the list of the 2012 Engineers' Choice honorable mentions.

View the list of the 2012 Engineers' Choice winners.

View the complete list of the 2012 Engineers' Choice finalists.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me