EC: Fluke Ti9 Thermal Imager

Hardware – Handheld test, measurement, calibration: The Fluke Ti9 thermal imager detects heat patterns or temperature changes in objects, allowing the user to discover problems prior to costly downtime, or to monitor developing problems so maintenance can be scheduled during a planned downtime or when budget is available. This is a Control Engineering 2012 Engineers’ Choice (EC) finalist.

11/17/2011


Fluke Ti9 Thermal Imager. The Fluke Ti9 thermal imager detects heat patterns or temperature changes in objects, allowing the user to discover problems prior to costly downtime, or to monitor developing problems so maintenance can be scheduled during a planned downtime or when budget is available. This is a Control Engineering 2012 Engineers’ Choice finalist.The Fluke Ti9 is a high-performance thermal imager that is ideal for troubleshooting electrical installations as well as electromechanical, process, and HVAC/R equipment. The Ti9 delivers Fluke rugged, reliable performance in an imager that is affordable and easy to use.

The Fluke Ti9 delivers crisp, clear images on a large widescreen full-VGA-color LCD display that allows technicians to view the full picture instantly. It features a thermal sensitivity of 0.20 C at 30 C target temperature (200 mK) to identify even small temperature differences that could indicate problems. The Ti9 is built to work in the harshest industrial environments. It has an IP54 rating for withstanding dust and water, and is designed to survive drops of up to 2 m. The built-in cover and lens guard protects the lens when not in use. The thermal imager has an intuitive three-button menu that allows users to navigate with the push of a thumb. They can simply point, focus, and shoot to capture an image.

Fluke SmartView professional IR analysis and reporting software is included with the Ti9. The suite of tools for viewing, annotating, editing, and analyzing infrared images enables users to edit images and generate customized professional reports in a few steps using the report wizard. The Fluke Ti9 Thermal Imager comes with a 2 GB SD memory card, multifunction memory card reader, rechargeable internal battery, ac charger/power supply, adjustable hand strap, soft carrying case, and rugged hard carrying case.

www.fluke.com

www.fluke.com/Fluke/usen/Thermal-Imaging/Fluke-Ti9.htm?PID=56189

Fluke Corp.

Return to the list of the 2012 Engineers' Choice finalists.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me