EC: Fluke 709H Precision Current Loop Calibrator with HART Communications

Hardware - Handheld test, measurement, calibration: The Fluke 709H is a precise loop calibrator and powerful HART communicator in one compact, rugged, reliable tool. This is a Control Engineering 2014 Engineers’ Choice finalist.

10/17/2013


Hardware - Handheld test, measurement, calibration: The Fluke 709H is a precise loop calibrator and powerful HART communicator in one compact, rugged, reliable tool. This is a Control Engineering 2014 Engineers’ Choice finalist.The Fluke 709H Precision Current Loop Calibrator with HART Communications is an affordable, easy-to-use tool with a user-friendly interface and HART capabilities that reduces the time it takes to measure or source, voltage or current, and power up a loop. With its best-in-class accuracy at 0.01 percent reading, the Fluke 709H is ideal for process technicians who need a precise loop calibrator and powerful HART communicator in one compact, rugged, reliable tool.

The 709H supports a select set of HART universal and common practice commands. In the communicator mode, technicians can read basic device information, perform diagnostic tests, and trim the calibration on most HART-enabled transmitters. In the past, this could only be done with a dedicated communicator, a high-end multifunction calibrator, or a laptop computer with a HART modem. It also features a built-in, selectable 250-ohm resistor to tune the loop for HART communications.

The 709H and non-HART 709 models feature an intuitive interface with dedicated buttons, a Quick-Set rotary encoder knob, and simple two wire connection for quick, easy measurements. The dedicated 0-100 percent span and 25 percent step buttons make for quick and easy testing. Ramping and auto-stepping enables technicians to perform tests remotely and be in "two places at once."

The optional 709H/TRACK software with communication cable can document milliamp measurements and HART transmitter parameters and upload to a PC.

www.fluke.com

www.fluke.com/fluke/usen/process-calibration-tools/loop-calibrators/Fluke-709H-Precision-Loop-Calibrator-with-HART.htm?PID=75865 Fluke Corp.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me