SEARCH Archives
Loading
Sponsored by:

EC: Fiber Optic Absolute Position Sensor

Machine and embedded control – Discrete sensors: The Micronor MR330 Fiber Optic Absolute Position Sensor is an all-photonic rotary absolute position solution that withstands lightning, is immune to electromagnetic interference and magnetic fields, and is resistant to radiation and high temperature—all with 13-bit resolution and 0.025% accuracy. This is a Control Engineering 2012 Engineers’ Choice award winner.

11/17/2011


Fiber Optic Absolute Position Sensor. The MR330 Fiber Optic Absolute Position Sensor is an all-photonic rotary absolute position solution that withstands lightning, is immune to electromagnetic interference and magnetic fields, and is resistant to radiation and high temperature—all with 13-bit resolution and 0.025% accuracy. This is a Control Engineering 2012 Engineers’ Choice finalist.The Micronor MR330 Fiber Optic Position Sensor System is an innovative all-optical design immune to any electromagnetic interference such as lightning, radiation, magnetic fields and other harsh environmental conditions. The sensor is entirely passive and intrinsically safe, ideal for use in hazardous locations and explosive atmospheres. The fiber optic aspect of the sensor also makes it perfectly suited for long-distance position sensing over hundreds of meters without being affected by ground loop problems. This innovative product measures absolute angular position from 0-deg to 360-deg with 13-bit (8192 count) resolution at speeds exceeding 2,500 rpm and distances up to 300 meters.

The sensor’s design was inspired by customers looking for a reliable solution intended for the applications listed below. Since its release in May 2011, the sensor has already been deployed in several of the following fields:

  1. Position sensing in areas where lightning strikes are likely: wind turbines, aerial tramways, positioning of satellite and deep space antennae.
  2. Deployment in high EMI (electromagnetic interference): aerospace actuator systems (electronic warfare), power generators
  3. Remote sensing spanning long distances: mining applications (no ground loop interference)
  4. Sparking (inherent safety), deployment in hazardous environments: oil rigs, mining, etc. Functions as a simple mechanical device.
  5. Unaffected by high-voltage potentials: particle accelerators; monitoring of power lines, monitoring of railroad overhead Lines.
  6. Aluminum smelters; positioning of the electrodes. Here the sensor withstands high temperatures as well as the high EMI fields during the melting process.

www.micronor.com

http://bit.ly/v3iNX0

Micronor Inc.

Return to the list of the 2012 Engineers' Choice award winners.

View the list of the 2012 Engineers' Choice honorable mentions.

View the complete list of the 2012 Engineers' Choice finalists.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.