EC: CoDeSys Embedded Controller CPX-CEC

Machine and Embedded Control - PLCs: Festo Corporation, CoDeSys Embedded Controller CPX-CEC. The CPX-CEC embedded controller from Festo Corporation is an intelligent remote I/O terminal with direct machine mounting that facilitates integration of pneumatics, electric drives, and I/O on the same compact controller with up to 31 electric drives and up to 512 I/O. This is a Control Engineering 2011 Engineers' Choice (EC) Honorable Mention.

11/01/2010


CoDeSys Embedded Controller CPX-CEC - The CPX-CEC embedded controller from Festo Corporation is an intelligent remote I/O terminal with direct machine mounting that facilitates integration of pneumatics, electric drives, and I/O on the same compact controller with up to 31 electric drives and up to 512 I/O. This is a Control Engineering 2011 Engineers' Choice (EC) nominee.The CPX-CEC embedded controller from Festo Corporation is an intelligent remote I/O terminal with direct machine mounting that facilitates integration of pneumatics, electric drives, and I/O on the same compact controller, up to 31 electric drives and up to 512 I/O. Its CAN-Master functionality delivers flexibility, open-and closed-loop standalone control for economical automation or remote control with pre-processing. The CPX-CEC offers fast cycle times of 1ms. The comprehensive CoDeSys function library takes care of diagnostics and condition monitoring options. These units meet both IEC 61131-3 programming standards and IP65/IP67 enclosure protection standards.

CPX-CEC Functions:

  • PLC control for valve terminal configurations with MPA, VTSA
  • Connection to all most industry fieldbus standards as an intelligent slave to provide local processing
  • PLC with CANopen master as standard for activation of electric drives or most 3rd party CANopen device
  • Diagnostics with flexible monitoring possibilities for pressure, flow rate, cylinder run time, air consumption, early warnings and visualization options
  • Activation of decentralized installation systems on the basis of CPI
  • Activation of applications of proportional pneumatics
  • Servo-pneumatic applications AS-interface control via Gateway
  • CoDeSys ensures simple commissioning, fast programming, and parameterization.

www.festo.com

www.festo.com/cms/en-us_us/12886.htm

Festo Corporation

For more, see www.controleng.com/awards.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me