Dynamic Lighting for a Kinetic Environment

When Sega GameWorks, a chain of dining and entertainment facilities, opened its first site in Seattle, the concept for the lighting design was to create an atmosphere of arcade entertainment combined with dining and music experiences. Plans were also made to use the same at facilities to be opened in Las Vegas and Ontario, Calif.

05/01/2001


When Sega GameWorks, a chain of dining and entertainment facilities, opened its first site in Seattle, the concept for the lighting design was to create an atmosphere of arcade entertainment combined with dining and music experiences. Plans were also made to use the same at facilities to be opened in Las Vegas and Ontario, Calif.

However, demographic data from the first sites suggested the need for a more kinetic design, so designers from the firm Moody Ravitz Hollingsworth (MRH), Van Nuys, Calif., were given the challenge of designing venues with more of a nightclub feel and less of an arcade look.

Adapting the design

In the new design scheme, a combination of 50-watt parabolic aluminized reflector (PAR)-30 and 120-watt PAR-38 halogen lamps were used as the key lighting sources, replacing 50-watt PAR-20 lamps specified in the original design. In addition, the team blended 32-watt and 17-watt T8 rapid-start fluorescent lamps with a combination of energy-efficient 50-watt halogen lamps in the arcade, dining and lounge areas. The kitchens are equipped with 32-watt fluorescents.

"The 50-watt and 120-watt halogens are the foundation of our design," says Dawn Hollingsworth, LC, principal of MRH. "We then layered in the light sources to achieve the total colorful environment we were looking for."

Facility managers have been supplied with an operations manual that has a complete lamp-replacement inventory, including specs and ordering codes.

For more information about lamps from Osram Sylvania, circle 102 on the Reader Service Card.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me