Dual channel brushless DC motor control

Roboteq's HBL2350 is capable of driving two brushless DC motors at 75 Amps and can accept commands from analog/pedal, R/C radio, USB or RS232 interface.

09/07/2011


Roboteq, Inc. introduces the HBL2350, an intelligent controller capable of simultaneously driving two brushless DC motor up to 75 Amps each at up to 50 V.

Roboteq’s HBL2350 is the world’s first dual channel, high current brushless motor controller, allowing users to implement 2-wheel drive small electric vehicles, automatic guided vehicles (AGVs), balancing scooters, or any other high power brushless motor control application.

The controller accepts commands from either analog pedal/joystick, standard R/C radio for simple remote controlled robot applications, USB or RS232 interface. Using the serial port, the HBL2350 can be used to design fully or semi-autonomous robots by connecting it to single board computers, wireless modems or WiFi adapters.

The HBL2350 incorporates a Basic Language Interpreter capable of executing over 50,000 Basic instructions per second. This feature can be used to write powerful scripts for adding custom functions, or for developing automated systems without the need for an external PLC or microcomputer.

The controller's two channels can be operated independently or combined to set the direction and rotation of a vehicle by coordinating the motors on each side (tank-like steering). The motors may be operated in open or closed loop speed or position modes with a 1 kHz update rate. The HBL2350 can use the motor’s hall sensors or optical encoders to measure speed and travelled distance with high accuracy.

The HBL2350 features intelligent current sensing that will automatically limit each of the power outputs to 75A in all load conditions. The controller also includes protection against overheat, stall, and short circuits.

The controller includes up to 11 analog, 19 digital and 6 pulse inputs. Eight 1A digital outputs are provided for activating lights, valves, brakes or other accessories. The controller’s operation can be optimized using nearly 80 configurable parameters, such as programmable acceleration or deceleration, amps limits, operating voltage range, use of I/O, and more.

A free PC utility is available for configuring, tuning and exercising the motor. The controller can be reprogrammed in the field with the latest features by downloading new operating firmware from Roboteq’s web site.

The HBL2350 is built into a compact 9.0-inch L x 5.5-in. W x 1.6-in. H (228 mm x 140 mm x 40 mm), robust extruded aluminum case, which also serves as a heat sink for its output power stage. The large fin area ensures sufficient heat dissipation for operation without a fan in most applications.

www.roboteq.com

Roboteq

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.