DIN-rail mounted surge protection protects control panels

The Varitector VSPC surge protection from Weidmuller is designed to protect control panel equipment from damage and breakdowns causes by local lightning strikes.

12/14/2011


The Varitector VSPC surge protection is designed to protect control panel equipment from damage and breakdowns causes by local lightning strikes. Courtesy: WeidmullerWeidmuller's DIN-rail mounted Varitector VSPC surge protection is a streamlined solution to protect control panel equipment from damage and breakdowns due to local lightning strikes. It is a means to effectively manage the protection of signal circuits in Control and Instrumentation applications.

Weidmuller’s Varitector VSPC includes over 60 models with a robust range of pluggable, replaceable, single- and multi-channel modular surge protection devices (SPDs). Meeting UL 497B requirements, VSPC provides a combination of wire-to-ground and wire-to-wire protection. The separate bases accommodate field connections and make a ground path from the SPD, via the (grounded) DIN-rail.

Targeted at measurement, control, and fieldbus applications, typically in Water and Waste sectors, VSPC is rated for discharge currents up to 20kA (8/20μs). A combination of gas discharge tubes, varistors and suppression diodes, in single- or multi-stage configurations are used to protect nominal voltages between 5 V dc and 230 V ac. VSPCs are suitable for analog current and voltage loops, dc and ac status signals, and a wide variety of serial interface and telephone network installations. To minimize panel rail space, various VPSC models with four conductors (e.g. two analog loops) can be protected by one 17.8mm (0.7inch) wide module.

The key to ensuring full, continued protection is the VSPC status monitoring option, which shows when the SPD module replacement is needed. The arrestor condition status is displayed on the device via a green/red indicator. An optional remote display is available via a separate VSPC Control Unit, where up to ten SPD modules may be connected. Other features include colored product marking to easily identify different working voltages between a group of modules mounted together on the rail, models for protecting floating signals, and a portable test accessory (V-TEST).

www.weidmuller.com 

Weidmuller

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.