Digital refrigerant leak detector

The RLD440 digital dual mode refrigerant leak detector is built for inspecting and maintaining mobile and stationary air conditioners, refrigerators, chillers, and heat pumps.

10/15/2014


General Tools & Instruments' RLD440 digital dual mode refrigerant leak detector is built for inspecting and maintaining mobile and stationary air conditioners, refrigerators, chillers and heat pumps. Courtesy: General Tools & InstrumentsGeneral Tools & Instruments' RLD440 digital dual mode refrigerant leak detector is built to detect HFC, HFO, HC, HCFC and CFC refrigerant gases. It is used for inspecting and maintaining mobile and stationary air conditioners, refrigerators, chillers and heat pumps. The RLD440’s has an ultraviolet (UV) detection to scan system components with UV light from three LEDs mounted on the end of the instrument’s grip. Any dye escaping from the system will glow a bright yellow-green. The solid electrolyte semiconductor sensor can pinpoint the source of a leak and gauge its size. Its three sensitivity levels let users choose the right level for specific environments. The RLD440’s automatic calibration and reset ensure accurate leak readings not distorted by ambient levels.

 

General Tools & Instruments

 

www.generaltools.com



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me