SEARCH Archives
Loading
Sponsored by:

Device profile underway for on-board weighing systems

CAN in Automation intends to develop the CANopen profile for on-board weighing systems with plans to release the first version of the draft standard proposal by the end of 2011.

Source: CAN in Automation (CiA)

03/05/2011


Members of CAN in Automation (CiA) have established the CANopen SIG (Special Interest Group) on-board weighing systems. They intend to develop the CANopen profile for on-board weighing systems. Experts from Celmi (IT), Dennis Eagle (GB), Moba (DE), Pfreundt (DE), and PM Vishay (GB) accepted the submitted CiA 459 work draft proposal (WDP) as discussion base.

The SIG plans to release the first version of the draft standard proposal (DSP) by end of 2011.

CANopen is used as body network in off-highway and off-road vehicles. In particular in battery-powered forklifts, it is also used as drive-train network. The proposed CANopen on-board weighing system is also suitable for truck-mounted bodies. A typical application is refuse collection trucks. Another application is truck-mounted cranes, which need information about the actual load of the truck.

The proposed device profile should simplify the integration in CANopen-based body control networks in any kind of vehicle, according to CANopen. This includes trucks as well as off-highway vehicles such as forklifts, agriculture and construction machines. The on-board weighing system may internally use a deeply embedded CANopen network linking the CiA 404 compatible load-cells. Alternatively the sensors are networked by other communication technologies including analog interfaces. The CANopen interface of the on-board weighing system hides these internal details. In case of deeply embedded CANopen networks, it is reportedly possible to implement the CiA 302-7 SDO/EMCY router, in order to access from the CANopen body network each sensors individually.

www.can-cia.org

CAN in Automation (CiA)

- Edited by Amanda McLeman, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

What percentage of your time is spent commissioning building projects?
0% to 25%
26% to 50%
51% to 75%
75% to 100%


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.