Designing a winning sports venue: HVAC systems

consulting-specifying engineer, consulting engineer, sports arena, entertainment venue, building code standard, ballpark, football field, HVAC, variable air volume, chiller plant, variable frequency drive

04/28/2014


Jerry Atienza, EIT Douglas H. Evans, PE, FSFPETodd Mack, PEJeff Sawarynski, PE, LEED AP

  • Jerry Atienza, EIT, Senior plumbing designer, Interface Engineering, Portland, Ore.
  • Douglas H. Evans, PE, FSFPE, Fire protection engineer, Clark County Dept. of, Development Services, Building Division, Las Vegas
  • Todd Mack, PE, Principal, DLR Group, Omaha, Neb.
  • Jeff Sawarynski, PE, LEED AP, Principal, M-E Engineers Inc., Denver, Colo.

The DLR Group MEP design for the Nebraska Athletics Performance Lab used galvanized steel supply and return ductwork extended from the duct chase into the stadium concourse to feed variable air volume (VAV) boxes. Courtesy: DLR GroupCSE: What unique HVAC requirements do sports/entertainment structures have that you wouldn’t encounter on other structures?

Evans: HVAC systems may also be designed to provide smoke management functions. This can substantially complicate the HVAC design. The designers must determine if it is more cost effective to have a dedicated smoke management system, or if it should be combined with the HVAC system. In order to design the smoke management system, the expected fire size must be taken into account. If the design intends to keep smoke above head height to allow safe evacuation, this can further complicate the smoke management design.

Sawarynski: Very high turn-down rates for part load events must often be analyzed and the systems designed to accommodate that. Life safety systems are often integrated at a more granular level than in other building types.

CSE: What changes in fans, variable frequency drives, and other related equipment have you experienced?

Mack: We see increased use of direct-drive plenum fans arranged in a fan wall/fan array arrangement on many air handling units (AHU). The use of fan wall technology generally allows for a smaller AHU footprint in the AHU’s fan section. With a fan array there are more, small fans arranged in parallel airflow paths that move the air at slower rpm than a conventional single fan AHU. Slower rpm usually translates to quieter installation. Another benefit of the fan wall technology is the inherent fan redundancy.

Evans: VFDs are becoming common for controlling smoke-control fans. They provide the ability to adjust the air quantity to compensate for construction differences and time of year, and can be adjusted if needed as the building ages.

CSE: With regard to stadiums that have unique humidity challenges (ice arenas, pools, aquariums, etc.), how have you solved these challenges? What ventilation or dehumidification tactics have you specified?

Sawarynski: We have used cold chilled water systems (i.e., 35 F chilled water), energy recovery dehumidifiers that use compression cycles, and dedicated desiccant systems. Depending on the performance requirements of the building, any of these approaches may prove the correct approach.

Mack: We are currently designing the Breslow Ice Center in Lincoln, Neb. The primary function of an HVAC system in an ice rink is to provide dehumidification while providing fresh air for ventilation and spectator comfort. The dehumidification equipment we intend to specify will incorporate an enthalpy wheel to reduce the work required by the active desiccant dehumidification portion of the equipment and provide lower operating costs. Desiccant systems use adsorption or absorption to remove moisture from rink air. These systems can provide arena ventilation while delivering dew-point temperatures below freezing. Having both good temperature and humidity control in the arena helps to reduce sensible and latent heat gains to the ice surface.



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Boiler basics; 2017 Product of the Year winners; Manufacturing facilities Q&A; Building integration; Piping and pumping systems
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Power system design for high-performance buildings; mitigating arc flash hazards
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me