Desiccant dehumidification system

Ascendant, a conventional cooling active desiccant dehumidification system, delivers and controls low-dewpoint air while minimizing regeneration energy.

04/14/2016


Ascendant, a conventional cooling active desiccant dehumidification system, delivers and controls low-dewpoint air while minimizing regeneration energy. Ascendant allows design consultant compliance with ASHRAE/AIA guidelines. Ascendant offers improved cooling efficiency through higher suction temperatures. Energy and first-cost savings allow hospitals, for example, to operate continuously around the clock, improving hygiene by ensuring that the ASHRAE-required final filters remain dry. An optional SEMCO true 3 Å wheel decreases tons of cooling outdoor air by up to 60%. A true 3 Å wheel also limits contaminant carry-over to less than 0.045%.

SEMCO

www.semcohvac.com


This product is a Finalist in the
Consulting-Specifying Engineer 2016 Product of the Year program. View more Finalists and cast your vote at www.csemag.com/votepoy (voting closes June 30, 2016).



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me