dc power distribution recommended practices

Use these three tips to ensure a direct current (dc) power distribution project is successful.

06/16/2014


1. Plan projects to include evaluation of alternatives, including dc systems. Opportunities may include the use of bulk rectifiers and dc buses for cooling fan and pump motors. Additionally, consider the dc voltage used by server equipment and providing a dc buses in the server aisle to feed this equipment. Connection of photovoltaic systems also typically includes a dc interface at less than 600 V.

2. Model the utility, generator, power converters, and loads to help develop interface standards, predict efficiency, validate the concept of operations, and identify key performance constraints, such as stability or harmonic distortion. Models can be used for energy management software development and testing. Many applications are suitable for this type of analysis.

3. Identify the power system equipment electrical interfaces, including harmonics, stability, and voltage requirements. Develop power distribution system architecture and interface standards appropriate for the project.


Jonathan Sauer is an electrical engineer at Jacobs Engineering. He works in the global building design group where he performs electrical systems engineering for buildings and mission critical data centers. Areas of expertise include facility electrical power, backup generation, UPS, automation, networks, commutations, security, fire, lighting, and HVAC.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me