DC electric motors with potentiometer offer power, control for incubator rotating mechanism

Bosch “VMC” DC electric motor with potentiometer features space-saving compact design, weighs approximately 0.12 kg, allows for easy installation into cabinet-style egg incubators, other industrial systems, and equipment.

SOURCE: Bosch

03/23/2011


Hens layBosch VMC Motor the eggs, but each year in the U.S. poultry industry, billions of baby chicks are hatched from those eggs by means of electric-powered egg incubators. To power the incubator’s rotating mechanism, which is essential to the development of healthy hatchlings, the Bosch i-Business Group offers the Bosch “VMC” dc electric motor with potentiometer. This 24-volt, 0.22-watt adjustment motor, which also offers design advantages for many different kinds of industrial applications, is one of several different 12V – 24 V dc electric motors with gear boxes that are featured in the Bosch VMC motor family.

The Bosch “VMC” dc electric motor with potentiometer features a space-saving compact design and weighs approximately 0.12 kg, allowing for easy installation into cabinet-style egg incubators and other industrial systems and equipment. The potentiometer, which is included with this model of Bosch VMC motor, is vital for incubator applications because it triggers the on/off electrical circuit for the incubator’s timed rotating mechanism.

Hatching eggs (fertile eggs) are rotated in large incubators to mimic the manner by which chickens and other fowl naturally, and frequently, turn over their “laid” eggs during that period when they sit on them (thereby incubating the eggs) and wait for their chicks to hatch. Hatching eggs must be rotated a few times throughout the day to ensure that the embryos do not stick to the interior walls of the eggs; otherwise the embryos will fail to develop.

Kenn Langosch, Sales Manager for Industrial Motors for Bosch, says, “Having dependable incubators is extremely important to the overall success of the poultry industry. The Bosch i-Business team can help the developers of incubators and other types of farm equipment ensure the reliability of their products by matching Bosch dc electric motors to their critical product design needs.”

The key design characteristics of the Bosch VMC motor with potentiometer include:

  • Nominal voltage: 24 V
  • Nominal power: 0.22 W
  • Nominal current: ≤ 55 mA
  • Maximum current: 250 mA
  • Nominal speed: 6 min-1
  • Rated torque: 40 Ncm
  • Breakaway torque: ≥ 100 Ncm
  • Reduction: 405 : 1
  • Direction of rotation: L/R (direction of rotation can be inverted by changing over +/-)
  • Shaft load max. axial: ≤ 30 N
  • Shaft load max. radial: ≤ 50 N

Bosch Industrial Motors

www.boschusa.com

Bosch

- Edited by Gust Gianos, Control Engineering, www.controleng.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity

Poll of the Week

When engineering systems in military buildings, what’s the most difficult issue you face?
Automation and controls
Codes and standards
Electrical and power
Energy efficiency, sustainability
Fire and life safety
HVAC


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.