Critical power: Generators and generator system design

When designing generator systems, consulting engineers must ensure that the generators and the building electrical systems that they support are appropriate for the specific application.

02/13/2014

Flash is required!

When designing generator systems, consulting engineers must ensure that the generators and the building electrical systems that they support are appropriate for the specific application. Whether providing standby power for health care facilities or prime power for rural processing plants, engineers must make decisions regarding generator sizing, load types, whether generators should be paralleled, fuel storage, switching scenarios, and many other criteria. In addition to being up to speed on the applicable codes, consulting engineers must work with the authorities having jurisdiction (AHJ) to ensure approval for the generator system is attained.

Learning objectives:

  • The audience will understand the applicable code requirements including NFPA 70: National Electrical Code and NFPA 110: Standard for Emergency and Standby Power Systems
  • Attendees will learn the criteria for selecting the appropriate generator or generators for the building type and/or application
  • Viewers will understand the criteria for designing the generator system, and know the differences between prime rated versus standby rated engines (U.S. EPA standards)
  • Viewers will learn the criteria for commissioning generators and the electrical systems they support.

Speakers:

James Ferris, PE, TLC Engineering for Architecture, Orlando, Fla.

Robert R. Jones Jr., PE, LEED AP, JBA Consulting Engineers, Las Vegas

Moderator: Jack Smith, Consulting-Specifying Engineer, Pure Power, and CFE Media, LLC



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me